Tabletop Series Technical Specifications

Computer and Software

  • Pentium™ 4 with CD-ROM Drive; 17” LCD Monitor and Video Monitor
  • Windows XP™ Operating System
  • Ethernet Network Port and RS232

Dispense Pump Options

  • Smart Pump™ 20: 20 picoliter control
  • Smart Pump™ 100: 100 picoliter control
    • Dynamic flow control allows for adjustment as material properties change over time
    • Precise starting and stopping without tailing; tight volumetric control
  • Positive Displacement Pump - nL control and cluster placement
  • Air Pressure Pump - nL control and high volume placement
  • Micro Mixer Pump - Real time 3 part mixing

Frame and Base

  • Machine Frame: Sicron supplied
  • Motion Base: Aluminum base, risers, and bridge

Input / Output

  • Digital I/O: 24 inputs, 24 outputs
  • Analog I/O: 3 inputs (12 bits), 3 outputs (16-bit)

Installation Requirements

  • Air Supply: 80 PSI to 120 PSI
  • Power: 120V at 30A
  Standard
X/Y Stage Type ATS115
Travel 300mm × 150mm
X/Y Resolution ±0.5µm
Repeatability ±2µm
Accuracy ±12µm
Maximum Travel Speed 300 mm/s
Maximum Linear Acceleration 1g–10 m/s2 (no-load)
Z Stage Type ATS115
Z Travel 100mm
Resolution 0.5µm
Repeatability ±1µm
Accuracy ±6µm
Maximum Travel Speed 300 mm/s
Motion Base Aluminum base,
risers, & bridge
Machine Frame Vendor Supplied
Digital I/O 24 inputs, 24 outputs
Analog I/O 3 inputs (12-bit)
3 outputs (16-bit)